Start here: the routine in brief
The commonest failure: the main filter is still sealed in its shipping plastic, so the fan pushes against a bag instead of drawing air through the media. Levoit: run without removing the plastic wrap and the purifier will not filter air and may overheat. Unwrap and seat the filter, place it with its manual's clearance, run it with doors and windows closed, clean the pre-filter as described for your model, and replace the main filter on its interval.
Before you start: what you need
You need: a vacuum with a hose or brush attachment; a soft brush; soft, dry cloths; cotton swabs for the sensor lens; and, when a change is due, the genuine replacement filter for your exact model.
Room temperature water only where allowed: washable pre-filters and the Winix Washable AOC Carbon Filter. Never for a Levoit Core filter or a main HEPA filter unless that exact filter is labelled washable.
Unboxing and first use: the step owners skip
Before the first run, and again with every new filter:
- Unplug, open the unit, take the filter out. Levoit Core: flip it over, twist the cover counterclockwise, lift off. Coway: pull the upper front cover forward. Winix: pull the front panel forward.
- Remove all plastic packaging. Levoit, as a safety instruction: do not use the purifier without removing the plastic wrap.
- Seat the filters in the maker's order. Coway: main filter first, pre-filter in front, pushed until its clip clicks. Winix: True HEPA back, carbon middle, pre-filter front. Levoit Core: no top or bottom, handle up.
- Close the cover properly. Coway lists a cover not closed among its no-air checks.
- Plug in and run. Reset the indicator afterwards (Step 5 below) if fitted outside its cycle.
Winix note: a new filter can smell as it settles (outgassing); run it a day or so, on high in a separate room if it bothers you. A later smell is different.
Where to place it and how to run it
The US EPA Guide to Air Cleaners in the Home says to put the unit in the room you spend the most time in, away from curtains and anything blocking airflow.
- Levoit Core: at least 15 in (38 cm) on all sides, on a flat, stable surface.
- Coway Airmega: at least 20 cm from walls, 30 to 60 cm clear above, at least 2 m from electronics such as a TV, away from strong artificial lighting or direct sunlight.
- Winix: at least 12 to 18 in from walls and from electronics, only on hard, flat surfaces; flimsy or slanted surfaces may cause noise and vibration.
Run it closed, and long enough. Levoit: keep windows and doors closed while it is on; for smoke, run at maximum for 15 to 20 minutes before dropping to a lower speed. The EPA: higher fan speeds and longer run times increase the amount of air filtered
Continuous running is maker-endorsed: The Winix America FAQ on leaving a purifier on all the time states you can leave a Winix purifier on all the time, and Winix recommends it: smart sensors adjust fan speed in auto mode. The EPA limit: a portable cleaner cannot remove all pollutants; filtration supplements source control and ventilation.
How to clean an air purifier
In order, machine unplugged.
Step 1: the pre-filter.
- Levoit Core: every 2 to 4 weeks, soft brush or vacuum hose. No water: it is the outer layer of the combined cartridge.
- Coway Airmega: every 2 to 4 weeks, vacuum or water depending on contamination; if washed, install only after removing the moisture completely. Coway's own guide to cleaning an Airmega gives the same rhythm.
- Winix (5500-2): every 14 days, vacuum or soft brush; if excessively soiled, rinse in room temperature water, no detergent or soap, dry 24 hours or more. The pre-filter is permanent.
Step 2: the main filter, which you do not wash. Levoit marks its True HEPA and activated carbon filter "do not clean." Coway: its main filter cannot be cleaned or reused, never with water. Winix: do not wash and reuse the True HEPA Filter. One exception: the Winix Washable AOC Carbon Filter (5500-2), rinsed in room temperature water every 3 months, no detergent, dried 24 hours or more, never in hot water over 104 degrees F, used only when completely dry.
Step 3: housing and inside. Levoit: soft, dry cloth outside (damp only if necessary, dried immediately), vacuum inside, no abrasive or flammable agents. Winix, every 1 to 2 months: vacuum the interior, wipe inside and out with a damp cloth, then dry. Coway: body every 2 to 4 weeks, dry soft cloth.
Step 4: the sensor, if fitted. Coway, every 2 months: brush or vacuum vents and sensor; clean lens, dust inlet and outlet with a lightly wet cotton swab, then a dry one. Without it, sensor performance deteriorates.
Step 5: reset the indicator after a filter change. Levoit: unit on, hold the Check Filter Indicator 3 seconds until off (if changed before it lit: 3 seconds on, then again 3 seconds off). Coway: hold Reset 2 seconds. Winix: unit on, hold the Filter Reset Button at least 5 seconds until the beep; use a paper clip where recessed.
Air purifier maintenance checklist
Each interval stays beside its maker; differing figures are printed, not averaged.
| Task | How often | Source |
|---|---|---|
| Clean pre-filter, brush or vacuum (do not wash) | Every 2 to 4 weeks | Levoit, Core manual |
| Clean pre-filter, vacuum or water, dry completely | Every 2 to 4 weeks | Coway, Airmega manual |
| Clean pre-filter, vacuum or brush; rinse only if excessively soiled, dry 24 hours or more | Every 14 days | Winix, 5500-2 manual |
| Replace main 3-stage filter | Every 6 to 8 months | Levoit, Core manual |
| Replace main filter set | True HEPA about 1 year; deodorisation about 6 months | Coway, Airmega documentation |
| Replace True HEPA filter | About every 12 months, or when the indicator lights | Winix, support and manual |
| Rinse Washable AOC Carbon Filter (labelled type only), dry 24 hours or more | Once every 3 months | Winix, 5500-2 manual |
| Clean sensor lens and vents | Every 2 months | Coway, Airmega manual |
How often should you clean an air purifier
"Clean" and "replace" are two different clocks. Cleaning runs in weeks; replacement runs in months, per the checklist above. The EPA gives the reason: all filters need regular replacement, and a dirty, overloaded filter will not work well. The main filter is replaced, not washed.
How to store an air purifier properly
Levoit: for extended non-use, wrap both the purifier and the filter in plastic packaging and store in a dry place, to avoid moisture damage. Moisture can leave a filter surface mouldy.
Clean it first; let any washed pre-filter dry completely (Winix: 24 hours or more). Store upright, covered and dry.
Troubleshooting: when the purifier is not doing its job
| Problem | Likely cause | Fix |
|---|---|---|
| Filter light will not reset | Indicator never reset, or filter due | Replace if due; unit on, hold reset: 3 seconds Levoit, 2 seconds Coway, 5 seconds until the beep Winix |
| Airflow feels weak | Filter still packaged, pre-filter clogged, clearance blocked, main filter at end of life | Check packaging removed, filter in place (Levoit); clean pre-filter; restore clearance; replace if due |
| Odour from the unit | Saturated carbon, contaminated filters, washable carbon refitted damp | Replace carbon and HEPA, clean or wash pre-filter (Winix); fully dry a washable carbon filter (Levoit) |
| Rattling or unusual noise | Filter not in place, packaging on, uneven surface, foreign object inside | Check filter and packaging (Levoit); move to a hard, flat surface; if damaged, stop and contact support |
Mistakes that damage an air purifier
- Running it with the filter still bagged. Levoit: the purifier will not filter air and may overheat.
- Washing a non-washable HEPA filter. Levoit: main filter is do not clean; Coway: main filter cannot be cleaned and reused, never with water; Winix: do not wash and reuse the True HEPA Filter.
- Blocking the intake against a wall or curtains. Winix: blocked vents may lead to increased internal temperatures, product failure and deformation.
- Ignoring the indicator, or resetting it without changing the filter. Levoit names the signs: increased noise, decreased airflow, unusual odours, a clogged filter.
- Expecting it to fix a mould source. Expecting it to fix a mould source. The EPA states that air cleaners do not address the cause of mould and musty odours, because mould is caused by a water or moisture problem: solve the moisture source and clean up the mould. Levoit: purifiers cannot solve an existing mould problem. Also avoid essential oils on the filter and use in excessively humid areas.
Safety
Ozone, in the EPA's words. The EPA advises: avoid portable air cleaners and furnace or HVAC filters that intentionally produce ozone. Ozone is a lung irritant, and air cleaners containing electrostatic precipitators, ionizers, UV lights without adequate lamp coatings, and plasma air cleaners may emit ozone. The EPA points to lists of machines shown to emit little or no ozone from the California Air Resources Board and AHAM, in its EPA guidance on ozone and air cleaners. Winix states its purifiers are CARB compliant and below the CARB limit, with PlasmaWave switchable.
Electrical and handling basics. Levoit: always unplug before servicing; do not use it if it or its cord or plug is damaged; do not try to repair it yourself. Winix: ensure filters are inserted before running, because running without filters can shorten its lifespan and cause electric shock or damage; unplug before cleaning; no benzene, alcohol or other volatile fluids, or flammable sprays or liquid detergents. Coway: unplug before cleaning; do not spray water directly; no detergents with organic solvents, bleach, chlorine or abrasives. Winix also states the unit will not remove carbon monoxide: it is not a gas alarm.
When to repair, when to replace
Replace the part when: the indicator lights; airflow dropped and cleaning the pre-filter did not restore it; odours persist because the carbon stage is saturated; or noise and airflow changed together.
Consider the machine finished when: the fan or motor fails; it will not run with a sound cord, good outlet and closed cover (Coway's checks); genuine filters for your model are unavailable; or it is damaged. Levoit and Winix both say: do not repair a damaged unit yourself; stop using it and contact support; never disassemble, repair or modify it.
If a replacement machine is the answer, size it first: AHAM's air filtration standards and CADR two-thirds sizing rule set the smoke CADR a room needs at at least two-thirds of its area in square feet. See our How to Choose an Air Purifier: Types, Features and Sizes Explained and Best Air Purifier for Home guides. If the room's problem is damp or dry air, not particles, see Air Purifier vs Humidifier.
Replacement parts worth knowing about
Match the part number to your exact model first: near-identical model names take different filters.

Levoit Core 300-RF Replacement Filter
A genuine Levoit cartridge with 3 stages, for the Core 300 and Core 300S. Change it every 6 to 8 months. Check the label on your old filter first and match it to Core 300-RF, because other Core models use different cartridges.

Coway Airmega AP-1512HH-FP Filter Replacement Set
A genuine Coway set for the Airmega AP-1512HH and 200M. In the box are one True HEPA filter and two deodorisation filters. Change the True HEPA at about 1 year and each deodorisation filter at about 6 months. It fits those two models only.

Winix 116130 Replacement Filter H
A genuine Winix set for the Winix 5500-2, with one True HEPA filter and one Washable AOC Carbon Filter. Change it every 12 months. Match the model exactly: the 5500-2 takes Filter H, while the older 5500 takes a different filter.
If your unit needs replacing outright, see our Best Air Purifier Under 150 guide.
Air Purifier: Frequently Asked Questions
How often should you clean an air purifier?
Clean the pre-filter every 2 to 4 weeks (Levoit, Coway) and every 14 days (Winix), by the method for your model: water is ruled out for the Levoit Core pre-filter, and a rinse is allowed on Coway and Winix. The main filter is never cleaned: it is replaced, on the checklist intervals.
How can you make an air purifier last longer?
Keep the pre-filter clean and replace the main filter on its interval, not beyond it. Keep the unit out of excessively humid rooms and essential oils away from the filter. Nothing supports extending a main filter's life by washing it.
How do you store an air purifier you are not using?
Clean it first; let any washed pre-filter dry completely (24 hours or more on Winix's instruction). Levoit: wrap the purifier and filter in plastic packaging and store in a dry place to avoid moisture damage. On return, check the filter is unwrapped and seated, and count the time away against its remaining life.
What mistakes damage an air purifier most quickly?
Running it with the filter still in its plastic packaging, washing a main HEPA filter marked do not clean, and pushing it flat against a wall or curtains so its intake is blocked. Close behind: ignoring the indicator.
When should you replace an air purifier instead of its filter?
Replace the filter when the signs are filter signs: the indicator, weak airflow cleaning does not restore, persistent odour from a saturated carbon stage. Replace the machine when the fan or motor has failed, when it will not run after the power and cover checks, when damaged, or when genuine filters for your model are no longer sold.
Keep researching this air purifier
the buying shortlist, with the strongest verified purifiers compared at every room size for owners whose current machine is beyond a filter change.
Budget BuyingBest Air Purifier Under 150the same buying decision under a fixed budget ceiling, for a replacement machine rather than a replacement filter.
ComparisonAir Purifier vs Humidifierparticles versus moisture, the prior question for rooms where the problem itself is still in doubt.
How to ChooseHow to Choose an Air Purifierroom size, CADR, filter wording and noise explained in full, for sizing a replacement correctly the first time.
More in Home & Cleaning
Home & CleaningAll Pick Hearth guides in this categoryHow we check care guides like these
Read the full Pick Hearth methodology- Every instruction and interval traced to the manufacturer manual or official support page named in our research notes: Levoit, Coway and Winix for intervals, methods, resets and clearances, and the US EPA Guide to Air Cleaners in the Home for run time, mould and ozone wording.
- Where makers disagree we print each maker's figure rather than averaging: pre-filter cleaning every 2 to 4 weeks (Levoit, Coway), every 14 days (Winix); main filter life 6 to 8 months (Levoit), about 12 months (Coway, Winix).
- No brand can pay for a place, and affiliate earnings never change the guidance: the parts listed are the makers' own replacement filters, this category's genuine consumable.
First published · Updated in place as manuals and guidance change